The Fiber Plant: Fibers, Splices and Tracing
Every fiber in your cables with its colour, splice diagrams for closures, cabinets, splitters and OLTs, and a trace from the OLT to the customer with the light budget.

The fiber plant is the inside of your fiber cables: every fiber with its colour, what it is spliced to in each closure, which splitter port it feeds and which customer it ends at. You record it on the network map you already have, and ISPBox uses it to trace the light from the OLT to a customer and work out the light budget on the way.
It works for any fiber network: a GPON or XGS-PON plant with splitters, point-to-point fiber, or fiber backhaul between towers.
1. Fibers in a cable
Every fiber cable on the map (a Fiber Route, or your own cable type that works like one) gets its fibers as soon as it has a fiber count. Select the cable and open the Cable tab: the Fibers card has three fields.
- Fibers total: 2, 12, 48, 144 and so on.
- Per tube: how many fibers each tube (buffer tube) holds. Empty means 12, or all of them in a cable of 12 or fewer.
- Colours: the colour code of the cable, TIA-598 (blue, orange, green, brown, slate, white, red, black, yellow, violet, rose, aqua) or DIN VDE 0888. Tubes take the same colours. Past the 12th fiber in a tube the colours repeat with a stripe.
The Fibers tab of the cable lists them tube by tube. Each fiber shows its number, its colour and its state: used (spliced or connected at either end), reserved, damaged or free, and what it is joined to at both ends of the cable. The bar at the top adds them up.

In edit mode you can reserve a free fiber (with a note on what it is kept for) or mark one damaged (with where and how you know, for example an OTDR reading). A used fiber gets its state from its splices, so it cannot be changed here.
A cable that already had used and reserved counts typed in before keeps them: its first fibers become used and the next ones reserved, so nothing is lost. A cable cannot be saved with fewer fibers while a fiber that would go is spliced: ISPBox names the fibers to take apart first.
2. The splice diagram
Every place that holds fiber has a splice diagram: a splice closure, a cabinet (with everything in it, including the boxes inside it), a splitter, an OLT, a customer's ONT. Select the place on the map and open its Splices tab for the numbers, then Open the splice diagram.

The diagram shows every cable that ends there with all its fibers, tube by tube, and every device there with its ports:
- a splitter: its input and its outputs, from its ratio (a 1:8 has 8 outputs);
- an OLT: its PON ports, read from your OLT system when it is connected, or a number you set under Ports here;
- a patch panel (ODF) in a cabinet or closure: as many ports as you set under Ports here. A patch panel port takes the fiber behind it and a patch cord in front;
- a customer's ONT: its fiber port.
Lines between the two sides are drawn in the fiber's colour. The arrows on a cable move it to the other side, so the cable coming in and the cable going out can face each other. Long port lists (a 48-port patch panel) show the ports in use and the next few free ones, with Show all.
Splicing one fiber
Click a fiber, then the fiber or port it joins. Choose how they are joined: fusion splice, mechanical splice, connector, or passes through (a fiber that runs through the closure uncut). Add the tray and slot it sits in, a measured loss if you have one, and a note, then Join.

Click a line, or a joined fiber, to change that splice or Take apart. Trace this fiber opens the trace (section 4).
ISPBox keeps the plant possible:
- a fiber is joined only at a place where its cable ends;
- each fiber end and each port takes one connection (a patch panel port two: the fiber behind it and the cord in front);
- a damaged fiber cannot be spliced;
- a device cannot lose a port that has a fiber on it (a splitter's ratio changed from 1:8 to 1:4 while output 6 is used is refused);
- archiving a place takes its splices apart and frees the fibers.
Splicing a whole cable or tube by colour
Under Splice by colour pick the cable coming in and the cable going out, and optionally one tube of each: fiber 1 goes to fiber 1, 2 to 2 and on, in one go. Fibers already joined, reserved or damaged are skipped and the count of fibers joined is shown. The same works to pass a whole tube through a closure uncut.
The splice sheet
Print splice sheet prints the diagram for the technician who goes to the closure.

3. Ports on an OLT and a patch panel
An OLT placed on the map and linked to your OLT system (see Fiber Network) shows its real PON ports, for example PON 0/1/3. Without the OLT system, set the number of PON ports under Ports here on its splice diagram. A cabinet or closure gets a patch panel the same way: set its number of ports. A number cannot go below a port that has a fiber on it.
4. Tracing the light
The trace follows the light through the plant and lists every step with its loss: the OLT's PON port, the patch panel, each splice, each fiber (cable, tube, colour, length), each splitter, down to the customer's ONT.

Open it from:
- Trace next to a fiber on a cable's Fibers tab;
- Trace this fiber on a splice;
- Trace this customer to the OLT on a customer's ONT on the map.
From a splitter output the trace goes up through the splitter to its input. From a splitter input it stops and lists the outputs, each a link to its own trace. A fiber that is joined to nothing, or a path that comes back to itself, is said as such, so missing splices are easy to find.
The light budget
When the path reaches an OLT port, the right side works out the budget:
- Total loss: everything on the way added up, with a bar showing how much is splitters, fiber, connectors and splices;
- Margin: what is left of the OLT's class (28 dB for class B+);
- Expected at the end: the OLT's light minus the loss.
When the customer's ONU is linked (see Fiber Network), the light it really measures is shown next to the plan. More than 1.5 dB below what the plan expects usually means a dirty connector or a tight bend: start with the connectors at both ends.
The light out of an OLT and its class are set on the OLT on the map (tab Details).
Usual losses
Where a splice has no measured loss, the budget uses the usual one. A map manager can change them under Usual losses on any trace, for the whole workspace:
- fiber 0.35 dB per km;
- fusion splice 0.05 dB, mechanical splice 0.3 dB, connector 0.5 dB, passing through 0 dB;
- splitters 1:2 3.7 dB, 1:4 7.3 dB, 1:8 10.5 dB, 1:16 13.7 dB, 1:32 17.1 dB, 1:64 20.5 dB, 1:128 24 dB;
- an OLT without its own values: 3 dBm out, class 28 dB, and the warning at 1.5 dB below the plan.
Use the usual values puts them all back.
5. On the schematic
The Network Schematic follows the fibers. A splitter lit from another splitter's output is drawn under that splitter, with a dotted line labelled with the output and the fiber length, even when the fiber runs back through closures on the way. Fiber cables carry how many of their fibers are used, for example 12C · 594 m · 3/12 used.

6. Who can do what
- Seeing the fibers, the splice diagrams and the traces needs View network map.
- Splicing, reserving fibers, setting ports and the usual losses needs Manage network map.